Price: $ 2,772 |
| PRICES SUBJECT TO CHANGE
WITHOUT NOTICE |
 |
 |
Description |
 |
| The Model
480 is a laboratory grade fluxmeter, for use with a Helmholtz coil
or custom search coils. This instrument measures the total flux of
a magnet part, which can be related to the magnetic field strength.
Applications include magnet testing, magnetizing, and automated field
measurement. In order to provide accurate and repeatable measurements,
automatic or manual drift compensation is available to the user. A
peak mode allows even the fastest magnetic pulse, such as those from
a magnetizer, to be accurately measured. The Model 480 is also useful
for measuring AC fields that are too high in frequency for a gaussmeter
to detect. Relay outputs and an external reset input allow for simple
automation functions to be implemented, while the RS232C and IEEE-488
ports permit advanced control of the fluxmeter via a remote computer
or automation equipment. |
 |
| General
Specifications |
| Input Type |
Two
lead (double-banana plug), ground referenced |
| Input Resistance |
100kOhm
or 10kOhm |
| Resolution |
0.0005mVs
(dependent on search coil type) |
| Accuracy, DC (displayed) |
±
0.25% of reading |
| Accuracy, AC (displayed) |
±
1% of reading (10 Hz - 10 kHz) |
| Frequency Range |
2 Hz
- 50 kHz |
| Update Rate |
5 readings
/ sec (display); up to 30 readings / sec on ports |
| Display Resolution |
±
5 3/4 digits (varies with measurement mode) |
| Measurement Modes |
DC,
DC Peak, AC, AC Peak |
| Measurement Features |
Peak
hold, automatic drift compensation, storage of setup parameters |
| Measurement Units |
V-s,
MxN, WbN, VsPhi, MxPhi, Gauss, Tesla, Wb-cm |
| Front Panel Display |
Vacuum-Flourescent,
high-visibiliy blue, 2 lines x 20 characters |
| Communication Ports |
RS232C
(9600 Baud) / IEEE-488 (complies with IEEE-488.2) |
| Alarms (3) |
Settings |
High/low
set point, inside/outside, audible |
| Actuators |
Display annunciator,
beeper, relays |
| Temperature Range |
15 -
35° C (operating temp; 5 - 40° with reduced accuracy) |
| Input Power |
100,
120, 220, 240 VAC 50/60Hz (select voltage when ordering) |
|
 |
| Analog
Outputs |
Analog
Output 1
(monitor output) |
Configuration |
Real-time
analog output voltage |
| Output Voltage |
± 3V = ±
FS on selected range |
| Accuracy |
Dependent on search
coil used |
| Frequency Response |
DC to 10 kHz |
Analog Output 2
(corrected output) |
Configuration |
Output voltage from
DAC |
| Output Voltage |
± 10V (Model
480-10: ± 10V) |
| Accuracy |
± 2.5 mV |
| Connector |
Detachable
terminal block |
|
 |
| Physical
|
| Net Weight |
6.6
lbs (3 kg) |
| Size (W x H x D) |
8.5" x 3.5"
x 12.5" (217mm x 90mm x 317mm; half-rack package) |
| Package Contents |
Fluxmeter, manual,
terminal-block mating connector, line cord |
| Software |
Labview driver (available
for download) |
|
 |
 |
|
|
|
|
|
|